Diffusion models can synthesise contrast-enhanced CT (CECT) from non-contrast CT (NCCT), avoiding contrast administration and its environmental and patient-access costs. However, visually realistic images are not necessarily anatomically correct, and the pixel-intensity and feature-space similarity metrics used to assess generation quality do not directly measure anatomical correctness. In this work, we investigate whether uncertainty can serve as a proxy for semantic correctness in diffusion-based medical image synthesis. We study NCCT-to-CECT synthesis using AortaDiff, a multitask diffusion framework that jointly generates CECT images and lumen segmentations. The segmentation output provides an explicit representation of the generated vascular anatomy, enabling segmentation-derived errors to be used as a quantitative measure of generation correctness. Six methods spanning weight (Ensemble, HyperDiff, BayesDiff), architecture-perturbation (MCDropout), generative-stochasticity (RDS) and input-perturbation (TTA) uncertainty are compared at the pixel, region and image levels, and for detection of clinically relevant out-of-distribution (OOD) cases. Uncertainty proves informative at…