STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites
Evaluating the energy transmission ratio of an X-ray beam through a polymer composite is a challenging task in radiation shielding studies. The reference solution with Monte Carlo transport simulation is highly accurate but computationally expensive: each of our reference simulations is capped at $4\times10^9$ photon histories and a 20,000 s (over 5 hours) time limit, while closed-form analytical methods fail to represent such complex scenarios. We present an artificial neural network model that maps the unordered multi-set of molecular constituents, their mass fractions, and four bulk physical descriptors directly to the transmission ratio $I(t)/I_0$ in 1-3 milliseconds. The model is a Set Transformer, which makes it permutation invariant by construction and accepts mixtures of different sizes up to 11 constituents within a fixed-size padded set. Each constituent is embedded with a chemistry-pretrained transformer language model, ChemBERTa. In our proposed method, training data are produced by an automated PENELOPE/penEasy pipeline using the radiation source at 30, 80, 100, and 120 kV tube voltages over polyethylene-based shielding composite slabs of thicknesses spanning…
- arXiv
- 2610.28709
- Authors
- Can Erer, H. Birkan Yilmaz, Nebahat Aral
- Categories
- cs.LG · cs.AI