IFC-SSL-Bench: Benchmarking Self-Supervised Learning for Annotation-Efficient Multispectral Imaging Flow Cytometry
Imaging Flow Cytometry (IFC) generates large multispectral datasets, yet the need for expert annotations bottlenecks the development of supervised deep learning models. While Self-Supervised Learning (SSL) offers a solution, its application to IFC remains fragmented and lacks systematic benchmarking. To address this, we present IFC-SSL-Bench, a modular framework for evaluating SSL in IFC. We benchmark six SSL approaches across four backbones on two heterogeneous datasets. By assessing downstream classification performance across annotation regimes of the training sets (1%-100%), we quantify annotation efficiency and identify optimal configurations for high-dimensional biological imaging. SSL matches the performance of fully supervised baselines trained on 100% of annotated data while using as little as 5% of annotations for morphological classification, with advantages in low-data regimes below 5%. Across both datasets, the contrastive approach MoCo-v2 paired with ConvNeXt backbones emerged as the top-performing configuration, with ConvNeXtV1-T best for immunological synapse classification and ConvNeXtV2-T for morphological classification. We identify a clear pattern in transfer…
- arXiv
- 2610.31848
- Authors
- Angelo Jovin Yamachui Sitcheu, Roxana-Teodora Fetescu, Thomas Lautenschlager, Nils Friederich, Linus Schilpp and 4 more
- Categories
- cs.CV