What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer?
Wearable sports sensors can recognize actions on the device itself, where lower-precision numbers reduce model storage and memory traffic. Two 4-bit block-scaled formats, MXFP4 from the Open Compute Project, introduced in 2023, and NVFP4 from NVIDIA, introduced in 2025, are drawing interest. Published evaluations cover general deep-learning benchmarks and large language models; to our knowledge, nobody has yet measured what they cost a small wearable-sensor model. We train a 159,492-parameter 1D CNN to recognize four basketball actions from wrist-accelerometer data in Hang-Time HAR and test it on players it has never seen, using five-fold cross-validation grouped by player. Every comparison between number formats is made fold by fold. In full precision the model reaches 69.26\% macro-F1. Measured TFLite FP16 and INT8 models lose at most 0.16 percentage points. In simulation, 4-bit weights cost 1.45 points with MXFP4 and 0.72 points with NVFP4. When activations are quantized to 4 bits as well, MXFP4 loses 5.14 points and NVFP4 only 0.75, and NVFP4 comes out ahead in all five held-out-player folds. The ranking survives two alternative simulator settings, with NVFP4 leading by 3.49…
- arXiv
- 2611.04185
- Authors
- Megan Healy, Hossein Valavi
- Categories
- cs.LG