Quality and Similarity Indicators for Video-Based Heart Rate and Respiratory Rate Fusion: A Controlled Evaluation
Camera-based heart rate (HR) and respiratory rate (RR) estimates vary in reliability from window to window, and a common remedy is to fuse several extraction methods with weights from reference-free signal quality indicators. However, few studies test whether these indicators identify the most accurate method in each window or outperform simpler fusion. We evaluate 11 quality indicators and 8 inter-method similarity measures for fusing 7 HR and 10 RR extractors on four public datasets (75 test subjects). Filters, indicator directions, weighting parameters and a learned ridge baseline are selected on a separate five-subject set before testing. Fusion is compared with equal averaging, a constant typical-rate predictor, the best single method selected in advance and in hindsight, and a per-window oracle with a permutation-based null, using subject-level bootstrap confidence intervals. For HR, quality-weighted fusion reduced mean absolute error by 10.9% [5.2, 18.4] relative to averaging and by 15.6% [8.1, 23.1] relative to the method selected in advance, and was statistically indistinguishable from the best method selected in hindsight. Weighting methods by their agreement did not…
- arXiv
- 2611.21419
- Authors
- Nhi Nguyen, Le Nguyen, Manuel Lage Cañellas, Miguel Bordallo López, Constantino Álvarez Casado
- Categories
- cs.CV